Technical Product BulletinFOOD AND DRUG APPLICATION EPOXY ADHESIVE
PRODUCT DESCRIPTION:
AA-BOND FDA16
is a medium viscosity epoxy resin system specifically developed for medical device applications.
AA-BOND FDA16
has been tested in accordance with USP biological reactivity tests, in vivo and received Class VI approval.
PRODUCT PROPERTIES:
APPEARANCE
Amber
MIX RATIO,
BY WEIGHT
100:33 / Resin:Hardener
BENEFITS
Medium viscosity
low permeability
Good resistance
Class VI approved
CURE TYPE
Heat cure or Room temperature
TYPICAL APPLICATIONS
Bonding, laminating
By manufacturers of catheters
Hearing aids
dental products
Other biomedical instruments and devices
Repair applications by:
- Manufacturers of food preparation.
- Processing.
- Packaging equipment.
UNCURED PROPERTIES:
VISCOSITY
@ 25 °C CPS
4,700
@Temperature 77°F, 25°C
SPECIFIC GRAVITY, CURED
0.900 g/cc
POT LIFE
25 min
SOLID CONTENT
100%
VOLATILE ORGANIC COMPOUNDS (VOC) CONTENT
0.15
g/l
WATER ABSORPTION ,
AFTER 24 HR SATURATION, %
0.30
MECHANICAL PROPERTIES:
LAP SHEAR STRENGTH
(Alum to Alum)
2,100
24 hr @ 25°C
3300
4
hr
@ 65°C
HARDNESS, SHORE D
86
4 hrs @ 65°C
75
24 hrs @ 25°C
CURE SCHEDULE:
1 – 4 hours
@ 65°C
72 hours
@ 25°C
ELECTRICAL PROPERTIES:
VOLUME RESISTIVITY
1.20e+14
ohm-cm
THERMAL PROPERTIES:
CTE, LINEAR
29.4
µin/in-°F
@ 68 °F
GLASS TRANSITION TEMP,TG
97.0 °C, 207 °F
OPERATING TEMPERATURE
-70 to 145 °C
GENERAL INFORMATION:
For safe handling information on this product, consult the Material Safety Data Sheet, (MSDS).
HOW TO USE:
1)
Carefully clean and dry all surfaces to be bonded.
2)
Apply
AA-bond FDA16
completely mixed adhesive to the prepared surfaces, and gently press these surfaces together. Contact pressure is adequate for strong, reliable bonds; however, maintain contact until adhesive is completely cured.
3)
Some separation of components is common during shipping and storage. For this reason, it is recommended that the contents of the shipping container be thoroughly mixed prior to use.
4)
Some ingredients in this formulation provided may crystallize when subjected to low temperature storage. A gentle warming cycle of 52°C for 30 minutes prior to mixing components may be necessary. Crystallized epoxy components do not react as well as liquid components and should be re-dissolved prior to use for best results.
AVAILABILITY:
This epoxy can be supplied in various different packages.